簡(jian)要(yao)描述:上(shang)海(hai)康(kang)登(deng)電(dian)氣科技有限公(gong)司DHG-4-25/120多(duo)極(ji)管式滑(hua)觸(chu)線(xian)系(xi)列(lie)產(chan)品,並(bing)針(zhen)對國內(nei)起(qi)重(zhong)設施裸露(lu)滑(hua)線(xian)易(yi)發生(sheng)事(shi)故(gu)的情況(kuang)下創(chuang)新研制生(sheng)產(chan)的。該系(xi)列(lie)產(chan)品有(you)三個類型(xing):即(ji)復合型(xing)、方管型(xing)和拼合型(xing)安(an)全(quan)滑(hua)觸(chu)線(xian)為(wei)本(ben)廠產(chan)品。
產(chan)品型(xing)號(hao):
廠商(shang)性質:生(sheng)產(chan)廠家(jia)
更新時間(jian):2025-09-10
訪(fang) 問(wen) 量:1617壹、 DHG-4-25/120多(duo)極(ji)管式滑(hua)觸(chu)線(xian)產(chan)品介(jie)紹(shao)
(壹)供電(dian)安(an)全(quan)滑(hua)觸(chu)線(xian)系(xi)列(lie)產(chan)品是本(ben)廠參考(kao)國外(wai)有關資料(liao)和*產(chan)品,並(bing)針(zhen)對國內(nei)起(qi)重(zhong)設施滑線(xian)易(yi)發生(sheng)事(shi)故(gu)的情況(kuang)下創(chuang)新研制生(sheng)產(chan)的。該系(xi)列(lie)產(chan)品有(you)三個類型(xing):即(ji)復合型(xing)、方管型(xing)和拼合型(xing)安(an)全(quan)滑(hua)觸(chu)線(xian)為(wei)本(ben)廠產(chan)品。
(二(er))本(ben)所研(yan)制的供電(dian)安(an)全(quan)滑(hua)觸(chu)線(xian)系(xi)列(lie)產(chan)品齊(qi)全(quan),用(yong)途廣(guang)泛(fan),可用(yong)於(yu)廠礦、庫房、車(che)站(zhan)、港口(kou)碼頭(tou)等(deng)場(chang)所的起重(zhong)機械如:電動(dong)葫蘆(lu)、梁式和橋(qiao)式起(qi)重(zhong)機;電梯(ti)、自動(dong)化生(sheng)產(chan)線(xian)和其它移動(dong)操作(zuo)的導電設備。
(三)用(yong)戶可根(gen)據起(qi)重(zhong)機械型(xing)號(hao)正(zheng)確(que)選(xuan)擇適當(dang)規格(ge)的供電(dian)安(an)全(quan)滑(hua)觸(chu)線(xian),以(yi)達到(dao)既可滿(man)足起(qi)重(zhong)機械的用電(dian),又(you)可節(jie)電、節(jie)能(neng)、降低能(neng)耗等技(ji)術經濟指(zhi)標(biao)。
(四(si))正(zheng)確(que)選(xuan)用(yong)供電(dian)安(an)全(quan)滑(hua)觸(chu)線(xian)是獲(huo)得(de)*技術經濟效果(guo)的關鍵,據可靠性研究(jiu),采用(yong)本(ben)滑觸(chu)線(xian)可以(yi)使(shi)系(xi)統的可靠提高(gao)兩個數量級(ji)。用(yong)戶在(zai)選(xuan)用(yong)供電(dian)滑(hua)觸(chu)線(xian)時應詳細參閱本(ben)說明(ming)書,全(quan)面(mian)了(le)解(jie)產(chan)品性能、特(te)點等,從(cong)而獲(huo)得(de)*使(shi)用(yong)效果(guo)。
二、DHG多(duo)極(ji)管式滑(hua)觸(chu)線(xian)產(chan)品工(gong)作(zuo)原理、特(te)點和用(yong)途

(壹) 主(zhu)要(yao)部(bu)件(jian)及(ji)其工作(zuo)原理
供電(dian)安(an)全(quan)滑(hua)觸(chu)線(xian)裝置(zhi)由(you)導管,導電器兩(liang)主(zhu)要(yao)部(bu)件(jian)及(ji)壹些輔(fu)助(zhu)組(zu)件構(gou)成如圖(tu):
1、導管:是壹根(gen)半封閉的異(yi)形管狀部(bu)件,是安全(quan)滑(hua)觸(chu)線(xian)的主(zhu)體(ti)部分(fen)。其內部(bu)可根(gen)據需(xu)要(yao)嵌設2-9根 導軌作(zuo)為供電(dian)導線(xian),各(ge)導軌間(jian)相(xiang)互(hu)絕緣,並(bing)與(yu)外(wai)殼絕緣,從(cong)而保(bao)證(zheng)供電(dian)的安全(quan)性。並(bing)在(zai)帶(dai)電(dian)檢(jian)修(xiu)時有效地防止檢(jian)修(xiu)人員(yuan)觸(chu)電(dian)事(shi)故(gu)。本(ben)廠生(sheng)產(chan)的導管每條(tiao)長(chang)度4m,可以(yi)連(lian)接成任(ren)意需要(yao)長(chang)度,普(pu)遍導管制作成直線(xian)形,也可以(yi)按(an)特(te)殊需(xu)求(qiu)制成圓(yuan)弧形等。
2、導電器是在導管內運(yun)行的壹組(zu)電刷(shua)殼(ke)架,由(you)安(an)置(zhi)在(zai)用(yong)電(dian)機構(行車、小(xiao)車(che)、電動(dong)葫蘆(lu)等)上(shang)的拔叉(cha)(或(huo)牽引鏈條(tiao)等(deng))帶(dai)動(dong),使(shi)之(zhi)與(yu)用(yong)電機構成同步運(yun)行,將(jiang)通過(guo)導軌,電(dian)刷的電能(neng)傳輸到電動(dong)機或(huo)其它控制元(yuan)件。導電器電(dian)刷(shua)的極(ji)數有3-16極(ji)與(yu)導管中(zhong)導軌數(shu)相應。
(二(er)) 產(chan)品特(te)性
1、安全(quan):供電(dian)安(an)全(quan)滑(hua)觸(chu)線(xian)外(wai)殼(ke)系(xi)由(you)高(gao)絕緣性能的工程塑料(liao)制成。外(wai)殼防護等(deng)級(ji)可根(gen)據需(xu)要(yao)達到(dao)IP13.IP55級(ji),能防(fang)護雨、雪、霜(shuang)和冰(bing)凍(dong)襲擊(ji)以(yi)及(ji)異(yi)物(wu)觸(chu)及(ji)。產(chan)品經受(shou)多(duo)種環(huan)境(jing)條(tiao)件(jian)經驗(yan)。絕緣性能良(liang)好(hao),對(dui)檢(jian)修(xiu)人員(yuan)觸(chu)及(ji)輸電導管外部(bu)無(wu)任(ren)何(he)傷(shang)害。
2、可靠:輸電導軌導電性能 ,散(san)熱較(jiao)快(kuai),許用電(dian)流(liu)密(mi)度高(gao),阻(zu)抗(kang)值(zhi)低,線(xian)路(lu)損(sun)失(shi)小。電(dian)刷由(you)具(ju)有高(gao)導電性能,高(gao)耐磨性能的金(jin)屬(shu)銅、碳(tan)合金(jin)材料(liao)制成。導電器移(yi)動(dong)靈(ling)活(huo),定(ding)向(xiang)性能好,有效控制了接觸(chu)電(dian)弧和串(chuan)弧現(xian)象(xiang)。
3、經濟:供電(dian)安(an)全(quan)滑(hua)觸(chu)線(xian)裝置(zhi)結(jie)構(gou)簡(jian)單(dan),許用電(dian)流(liu)密(mi)度高(gao),電阻(zu)率低、電(dian)壓損(sun)耗低,可節(jie)電10%左右,實現(xian)以(yi)塑代(dai)鋼(gang),以(yi)塑代(dai)銅(tong),設計新穎(ying),無(wu)需(xu)其它絕緣結(jie)構(gou),無(wu)需(xu)補(bu)償(chang)線(xian),安(an)裝於(yu)起(qi)重(zhong)機控制室(shi)同側(ce)。節省(sheng)安裝材料(liao)和經費。
4、方便:供電(dian)安(an)全(quan)滑(hua)觸(chu)線(xian)裝置(zhi)將(jiang)多(duo)極(ji)母線(xian)集(ji)合於(yu)壹根(gen)導管之(zhi)中(zhong),組(zu)裝簡便。其固定(ding)支(zhi)架(jia),連(lian)接夾(jia)、懸吊裝置(zhi),均(jun)以(yi)通用件(jian)供應。裝拆、調整(zheng)、維(wei)修(xiu)亦十分(fen)方便。
(三)用(yong)途:供電(dian)安(an)全(quan)滑(hua)觸(chu)線(xian)裝置(zhi)可用(yong)於(yu)電(dian)動(dong)葫蘆(lu)、電動(dong)梁式和橋(qiao)式起(qi)重(zhong)機:堆垛(duo)機、機電產(chan)品的自動(dong)檢(jian)測(ce)線(xian),自(zi)動(dong)化生(sheng)產(chan)線(xian);移(yi)動(dong)式電(dian)動(dong)工具(ju)和其它的移動(dong)導電設備,以(yi)及(ji)廠礦、車(che)間(jian)、辦公(gong)場(chang)所內(nei)固定(ding)敷設母線(xian)槽(cao)。
三、DHG多(duo)極(ji)管式滑(hua)觸(chu)線(xian)產(chan)品結(jie)構(gou)型(xing)式適(shi)用(yong)場(chang)合及型(xing)號(hao)
(壹)結(jie)構(gou)型(xing)式:供電(dian)安(an)全(quan)滑(hua)觸(chu)線(xian)導管由鋁(lv)合金(jin)外殼(ke)(金(jin)屬(shu)型(xing))、塑管外包(bao)鋁(lv)合金(jin)外殼(ke)(復(fu)合型(xing))、塑導管、導電器、中(zhong)間(jian)連(lian)接器(供電(dian)器)、端蓋(端部供電(dian)器)與(yu)其它附(fu)件組(zu)成。導管形狀成方形、拼合形。
1、加強型(xing)工(gong)程塑料(liao)導管,其截面形狀成方形,適用於(yu)室(shi)外,環(huan)境(jing)溫(wen)度為-30度~+55度的場(chang)合,其導軌截面積有:10、16、25、35、50、70、95、140mm2等。其導軌極(ji)數有:3、4、5、7、8、16極(ji)等。其截面形狀如圖(tu):

2、金(jin)屬(shu)復合型(xing)導管:是在加強型(xing)號(hao)管外加壹層(ceng)鋁(lv)合金(jin)復合外殼(ke),以(yi)提(ti)高(gao)導管的耐溫及抗(kang)老化性能,適用於(yu)環(huan)境(jing)溫(wen)度-30度~+65度的室(shi)外及高(gao)溫車(che)間(jian)等(deng)場(chang)所,其截面形狀如圖(tu):

3、金(jin)屬(shu)性:金(jin)屬(shu)型(xing)導管采用(yong)鋁(lv)合金(jin)外殼(ke)並(bing)用(yong)絕(jue)緣保(bao)護(hu)材(cai)料(liao)制成,適(shi)用環(huan)境(jing)溫(wen)度為-40度~+80度的場(chang)合,其截面形狀如圖(tu)3-4。

4、 產(chan)品規(gui)格(ge)與(yu)品(pin)種見(jian)表(biao):
安全(quan)滑(hua)觸(chu)線(xian)規(gui)格(ge)及型(xing)號(hao)
1、 加強型(xing)工(gong)程塑料(liao)管及復(fu)合型(xing)塑管外包(bao)裝鋁(lv)合金(jin)外殼(ke)
| Smm2 | 截面積mm2 | |||||||||
| L級數 | 10 | 16 | 25 | 35 | 50 | 70 | 80 | 95 | 140 | 150 |
| 3 | a | a | a | a | a | a | a | a | a | a |
| 4 | a | a | a | a | a | a | a | |||
| 5 | a | a | a | a | a | a | a | |||
| 6 | a | a | a | a | a | a | a | |||
| 7 | a | a | a | a | a | a | a | |||
| 8 | a | |||||||||
| 16 | a | |||||||||
2、 金(jin)屬(shu)型(xing)(鋁(lv)合金(jin)外殼(ke))
| Smm2 | 截面積mm2 | |||||||||
| L級數 | 10 | 16 | 25 | 35 | 50 | 70 | 80 | 95 | 140 | 150 |
| 3 | a | a | a | a | a | a | ||||
| 4 | a | a | a | a | a | a | ||||
| 5 | a | a | a | a | a | a | ||||
| 6 | ||||||||||
| 7 | ||||||||||
| 8 | ||||||||||
| 16 | ||||||||||
(二) 型(xing)號(hao)
1、滑觸(chu)線(xian)導管型(xing)號(hao)標(biao)示(shi)法(1)(2)


2、導電器型(xing)號(hao)表(biao)示(shi)法

例(li):
1、 HTS-4-16/80A型(xing)安(an)全(quan)滑(hua)觸(chu)線(xian)加強型(xing)工(gong)程塑料(liao)導管4極(ji)截面積為16mm2,電流(liu)量為(wei)80A。
2、 HXTL-4-16-80/A型(xing)安(an)全(quan)滑(hua)觸(chu)線(xian)鋁(lv)合金(jin)外殼(ke)4極(ji)截面積為16mm2,電流(liu)量為(wei)80A。
3、 特(te)殊規(gui)格(ge)型(xing)號(hao),可特(te)殊加工制作。
(三)規(gui)格和基本(ben)參數(shu)
安全(quan)滑(hua)觸(chu)線(xian)規(gui)格(ge)和基本(ben)參數(shu)表(biao)
| 型(xing)號(hao) | 導軌 截面 mm2 | 導管35°C時zui大(da)連(lian)續(xu)載流(liu)量(A) | 級(ji)數(shu) | 可分(fen)別(bie)使(shi)用(yong)級數 | 配用導電器 | 適(shi)用(yong)起重(zhong) 機噸位(wei) | |
| 型(xing)號(hao) | 配用數(shu)量 | ||||||
| HXTS-4410/50 | 10 | 50 | 4 | 3.4.5.6.7.16 | JD-4-10/25 | 2 | 1-3 |
| HXTS-4-16/80 | 16 | 80 | 4 | 3.4.5.6.7 | JD-4-16/40 | 2 | 3-5 |
| HXTS-4-25/120 | 25 | 120 | 4 | 3.4.5.6.7 | JD-4-25/60 | 2 | 5-10 |
| HXTS-4-35/140 | 35 | 140 | 4 | 3.4.5.6.7 | JD-4-35/70 | 2 | 5-10 |
| HXTS-4-50/170 | 50 | 170 | 4 | 3.4.5.6.7 | JD-4-50/80 | 2 | 10-30 |
| HXTS-4-70/210 | 70 | 210 | 4 | 3.4.5.6.7 | JD-4-70/120 | 2 | 30-50 |
| HXTS-4-80/230 | 80 | 230 | 4 | 3.4.5.6.7 | JD-4-80/120 | 2 | 30-50 |
| HXTS-3-95/300 | 95 | 300 | 3 | 3 | JD-6-50/90 | 2 | 50-100 |
| HXTS-3-140/400 | 140 | 400 | 3 | 3 | JD-6-70/120 | 2 | 100 |
| HXTS-3-150/420 | 150 | 420 | 3 | 3 | JD-6-70/120 | 2 | 100 |
| HXTS-16-10/50 | 10 | 50 | 16 | 8.10.12.14.16 | JD-16-10/25 | 按(an)需(xu) | |
HXTS(L)安全(quan)滑(hua)觸(chu)線(xian)導軌物(wu)理參數
| 序(xu)號 | 導軌截面積 S | 35°C允(yun)許連續(xu)截流(liu)量(A) | 35°C百(bai)米(mi)電(dian)阻(zu)Ω | 50HZ、380V標(biao)準軌距(ju)允(yun)許載電流(liu)百(bai)米(mi)阻(zu)抗(kang) | |||||
| mm2 | w.t | Cu | AL | Ω | Ω | TC | |||
| 25% | 40% | 100% | |||||||
| 1 | 10 | 18×0.56 | 50 | 0.1823 | 0.184 | 60 | 40 | 33 | |
| 2 | 16 | 18×0.89 | 80 | 0.1140 | 0.116 | 100 | 68 | 53 | |
| 3 | 25 | 18×1.39 | 100 | 0.0729 | 0.075 | 120 | 92 | 66 | |
| 4 | 35 | 18×1.94 | 130 | 0.0529 | 0.055 | 170 | 128 | 86 | |
| 5 | 50 | 18×2.78 | 185 | 0.0365 | 0.040 | 240 | 184 | 121 | |
| 6 | 70 | 25×2.8 | 260 | 0.0260 | 0.028 | 367 | 288 | 184 | |
| 7 | 95 | 25×3.8 | 350 | 0.0192 | 0.025 | 434 | 338 | 217 | |
| 8 | 120 | 25×4.8 | 420 | 0.0152 | 0.022 | 553 | 435 | 276 | |
| 9 | 400 | 45×35 | 800 | 0.0075 | 0.017 | 1053 | 832 | 526 | |
| 10 | 600 | 45×35 | 1000 | 0.0050 | 0.015 | 1316 | 1040 | 658 | |
| 11 | 800 | 45×35 | 1200 | 0.0037 | 0.014 | 1580 | 1250 | 789 | |
導電器電(dian)刷(shua)物理(li)參數
,
| 材料(liao)型(xing)號(hao) | 電阻(zu)系(xi)數(shu)ρ (分(fen)接觸(chu)法) | 接觸(chu)電(dian)壓降△V | 摩(mo)擦系(xi)數(shu) μ | 500小(xiao)時磨損(sun) mm |
| TS-51/J164 | 0.1~0.35Ω.mm2 | 0.2~0.7 | ≤0.2 | ≤0.6 |
四(si)、產(chan)品主(zhu)要(yao)技(ji)術(shu)性能和使(shi)用(yong)環(huan)境(jing)
(壹)主(zhu)要(yao)技(ji)術(shu)性能與(yu)安(an)全(quan)指(zhi)標(biao)
| 序(xu)號 | 類別(bie) | |
| 1 | 極(ji)間(jian)對(dui)地絕緣電阻(zu) | >10MΩ |
| 2 | 絕(jue)緣介電強度 | 工頻(pin)交流(liu)3000V、1min無(wu)擊(ji)穿閃(shan)爍(shuo)現(xian)象(xiang) |
| 3 | 外(wai)殼防護等(deng)級(ji) | IP13IP55 |
| 4 | 電(dian)熱穩(wen)定(ding)性 | 20倍|額定(ding)1s |
| 5 | 耐化學腐蝕(shi)穩(wen)定(ding)性 | 耐酸、耐堿、耐鹽霧腐蝕(shi) |
| 6 | 環(huan)境(jing)指(zhi)標(biao) | 1、耐高(gao)溫試(shi)驗(yan):普(pu)通型(xing)+55°C 金(jin)屬(shu)復合型(xing)+65°C |
| 7 | 阻(zu)燃(ran)性 | 自熄 |
| 8 | 輸電導軌參(can)數 | 符合GB3049 電阻(zu)率≤0.02Ωmm2/(+20°C時) |
| 9 | 導電器 | 牽(qian)引力:F<80N;運(yun)動(dong)速度:V<200m/min |
| 10 | 電刷(shua)系(xi)數(shu) | 電(dian)阻(zu)系(xi)數(shu):0.1-0.35; 摩(mo)擦系(xi)數(shu):0.2 接觸(chu)壓降:0.3-0.1V;運(yun)行2000KM,磨損(sun)量<0.7mm 電(dian)刷(shua)有效磨損(sun):4-6mm;有效工(gong)作(zuo)壓力:1.8-2.3N/cm2 |
(二)使(shi)用(yong)環(huan)境(jing)條(tiao)件(jian)
1、環(huan)境(jing)溫(wen)度:加強型(xing)-30~+55°C
金(jin)屬(shu)殼復(fu)合型(xing)-30~+65°C 金(jin)屬(shu)拼合型(xing)-40~+80°C
2、大(da)氣條(tiao)件(jian):+20°C相對濕(shi)度不大(da)於(yu)95%
3、汙(wu)染(ran)等(deng)級:IP13 3級(ji)IP55 3級
4、振(zhen)動(dong)與(yu)沖(chong)擊(ji):10~2000Hz加速率49m/S2
五、產(chan)品組(zu)件說(shuo)明(ming)
(壹)供電(dian)導管:承載電源(yuan)導入(ru)的電流(liu)輸送到導電器,每根(gen)導管長為(wei)4M,亦可根(gen)據需(xu)方要(yao)求(qiu)訂(ding)做,規格(ge)參閱表(biao)3-1
(二)導電器:在(zai)導管內與(yu)導軌滑(hua)動(dong)接觸(chu)導入(ru)電流(liu),並(bing)向(xiang)其它移動(dong)式電(dian)器提(ti)供電(dian)流(liu)的裝置(zhi)(見(jian)圖(tu)5-1)。

(三)中(zhong)間(jian)進(jin)線(xian)盒(he):由(you)導管的中(zhong)部(bu)導入(ru)電源(yuan)電(dian)流(liu)的裝置(zhi)(圖(tu)5-2)
(四(si))端部進(jin)線(xian)盒(he):由(you)導管的頂端導入(ru)電源(yuan)電(dian)流(liu)的裝置(zhi)(圖(tu)5-3)

(五)連(lian)接夾(jia):位(wei)於(yu)相(xiang)鄰(lin)兩(liang)導管連接處(chu),作連(lian)接固定(ding)和絕(jue)緣(圖(tu)5-4)
(六(liu))定(ding)形夾(jia):保(bao)持(chi)導管不變形(圖(tu)5-5、5-6)

(七)撥(bo)叉(cha):向(xiang)導電器傳(chuan)遞(di)移動(dong)推力或(huo)拉力,並(bing)適(shi)度吸收(shou)傳(chuan)動(dong)誤差和傳(chuan)動(dong)沖擊(ji),撥叉(cha)可根(gen)據導電器數(shu)量和型(xing)號(hao)配用(圖(tu)5-7)
(八)室(shi)外安全(quan)滑(hua)觸(chu)線(xian)地溝(gou)結(jie)構(gou)



六、選(xuan)用(yong)產(chan)品應註(zhu)意事(shi)項(xiang)
(壹)導管選(xuan)用(yong)
1、查(zha)表(biao)法:根據(ju)負載配置(zhi)總(zong)功(gong)率,負載持續率、使(shi)用(yong)環(huan)境(jing)、起(qi)重(zhong)機械噸位(wei)及(ji)其額定(ding)工(gong)作(zuo)電(dian)流(liu),查(zha)表(biao)3-1或(huo)表(biao)6-1確定(ding)導管規格(ge)。
2、功(gong)率估算法
(1)根據(ju)負載特(te)點、估算負載總功(gong)率Σp
a.n負載同時工作(zuo):Σp=Pa+Pb+...+Pn
b.n個負載不同時工作(zuo):Σp=pa+pb+pc...
其中(zhong):pazui大(da)壹個負載功(gong)率;pb、pc其余(yu)二個可能(neng)同時動(dong)作的負載功(gong)率。
(2)根據(ju)下表(biao)查(zha)供電(dian)滑(hua)觸(chu)線(xian)導管承載線(xian)三相(xiang)交流(liu)功(gong)率PN保(bao)證(zheng)PN>Σp
負載持續率和許用環(huan)境(jing)溫(wen)以(yi)系(xi)數(shu)Kt和Kε進(jin)行修(xiu)正(zheng)。
吊車(che)功(gong)率——導管軌道(dao)截面速查(zha)表(biao)
| 吊車(che)類型(xing) | 起(qi)重(zhong)量(t) | 額定(ding)總(zong)功(gong)率(KW) | 電動(dong)機功(gong)率 | 額定(ding)負載持續率 ε=25% | 額定(ding)負載持續率ε=40% | ||||||
| 主(zhu)鉤(gou)(KW/A) | 副(fu)鉤(KW/A) | 大(da)車(che)(KW/A) | 小(xiao)車(che)(KW/A) | 計算電流(liu)|(A) | 導線(xian) 截面BBLX mm2 | 導管軌道(dao)截面 mm2 | 計算電流(liu)|(A) | 40°C時導管軌道(dao)截面mm2 | |||
| 電 動(dong) 葫 蘆(lu) | 0.5 | 1.1 | 0.8/3 | 0.3/0.9 | 3 | 2.5 | 10 | 10 | |||
| 1 | 2.8 | 2.2/6.4 | 0.6/1.9 | 6.4 | 2.5 | 10 | 10 | ||||
| 2 | 4.1 | 3.5/9.2 | 0.6/1.9 | 9.2 | 2.5 | 10 | 10 | ||||
| 3 | 6 | 5/13 | 1/2.9 | 9.2 | 2.5 | 10 | 10 | ||||
| 5 | 8.5 | 7.5/19.7 | 1/2.9 | 19.2 | 4 | 10 | 10 | ||||
| 梁 式 吊 車(che) | 0.5 | 3.3 | 0.8/3 | 2.5/5 | 0.3/0.9 | 5 | 2.5 | 10 | 10 | ||
| 1 | 5 | 2.2/6.4 | 2.5/5 | 0.6/1.9 | 6.4 | 2.5 | 10 | 10 | |||
| 2 | 6.3 | 3.5/9.2 | 2.2/5 | 0.6/1.9 | 9.2 | 2.5 | 10 | 10 | |||
| 3 | 8.9 | 5/13 | 2.2/5 | 1.7/3.7 | 13 | 2.5 | 10 | 10 | |||
| 5 | 11.4 | 7.5/19.7 | 2.2/5 | 1.7/3.7 | 19.7 | 4 | 10 | 10 | |||
| 橋(qiao) 式 吊 車(che) | 5 | 23.2 | 11/28 | 2.2/7.2 | 27.5 | 6 | 16 | 41 | 16 | ||
| 10 | 29.5 | 16/43 | 3.5/10 | 35 | 10 | 16 | 58 | 25 | |||
| 15/3 | 35.5 | 22/57 | 11/31 | 3.5/10 | 42 | 16 | 25 | 103 | 35 | ||
| 20/5 | 48.5 | 30/72 | 16/43 | 3.5/10 | 58 | 25 | 25 | 103 | 35 | ||
| 30/5 | 80 | 60/133 | 16/43 | 5/15 | 94 | 50 | 35 | 140 | 50 | ||
| 50/10 | 89.5 | 60/133 | 30/80 | 7.5/21 | 105 | 50 | 50 | 156 | 70 | ||
導管截流(liu)量修(xiu)正(zheng)系(xi)數(shu)
| 溫(wen)度°C | 25 | 30 | 35 | 40 | 50 | 55 | 60 |
| Kt溫 | 1 | 0.94 | 0.89 | 0.82 | 0.67 | 0.53 | 0.47 |
接電(dian)持(chi)續率修(xiu)正(zheng)系(xi)數(shu)表(biao)
| ε % | 100 | 60 | 40 | 25 | 15 | 10 |
| Kε接 | 1 | 1.24 | 1.47 | 1.85 | 2.35 | 2.85 |
3、電流(liu)估算法
(1)工作(zuo)電(dian)流(liu)If估算:按(an)負載的額定(ding)工(gong)作(zuo)電(dian)流(liu)選(xuan)用(yong)導管,當(dang)工作(zuo)溫度為40°C,壹般(ban)起(qi)重(zhong)機;
If-Ifa+Ifb+Ifc
Ifa-zui大(da)功(gong)率電機折算或(huo)負載持續率。
Jc=100%時的工作(zuo)電流(liu)
Ifb、Ifc-其余(yu)可能(neng)同時動(dong)作二(er)只電(dian)機,Ic=100%時折算工作電流(liu)。對於(yu)大(da)容(rong)量、多(duo)電(dian)機起重(zhong)機、由下列經驗(yan)公(gong)式計算。
If=Kalc+KbΣ |+A
其中(zhong):Ic-起(qi)重(zhong)機其余(yu)電機總電(dian)流(liu)(Jc=25%時)
Σ i-起重(zhong)機其余(yu)電機總電(dian)流(liu)(Jc=25%時)
A-其它負載工作電流(liu)壹般(ban)取(qu)10(A)
Ka、Kb-功(gong)率電流(liu)轉(zhuan)換(huan)系(xi)數(shu)表(biao)
| 電流(liu)、系(xi)數(shu)、起(qi)重(zhong)機類別(bie) | 輕(qing)極(ji)(M4) | 中(zhong)級(ji)(M5) | 重(zhong)機(M6) | 特(te)重(zhong)機(M7) | |
| 交流(liu)380V | Ka | 0.6 | 0.6 | 0.9 | 0.9 |
| Kb | 0.2 | 0.3 | 0.4 | 0.6 | |
| 直流(liu)220V | Ka | 1.2 | 1.2 | 1.8 | 1.8 |
| Kb | 0.4 | 0.6 | 0.8 | 1.2 | |
(2)查(zha)《吊車(che)功(gong)率—導管軌道(dao)截面速查(zha)表(biao)》確定(ding)選(xuan)用(yong)規(gui)格,保(bao)證(zheng)IN>1f
IN——導管35°C時連續(xu)載流(liu)量
4、電(dian)壓降校(xiao)核:長(chang)度在100m以(yi)內(nei)的導管按(an)功(gong)率或(huo)電流(liu)估算法選(xuan)用(yong)後,可不進(jin)行電壓降校(xiao)核。
(1)電(dian)壓降△U≈指(zhi)標(biao):壹般(ban)起(qi)重(zhong)機△U<7%,治(zhi)金(jin)起重(zhong)機△U<5%,其它用電設施根據產(chan)品標(biao)準要(yao)求(qiu)。
(2)校(xiao)核方法:三相(xiang)交流(liu)負載:
△U≈173lmaxLcosψ % 直流(liu)負載: △U≈200lmaxL %
δSUn δSUn
其中(zhong)L-供電(dian)滑(hua)觸(chu)線(xian)裝置(zhi)計算長度m(見(jian)供電(dian)方式)。
δ-導電率,銅取(qu)50m/Ωmm2
S-導軌截面積mm2
Un-額定(ding)工(gong)作(zuo)電(dian)壓
COSψ-功(gong)率因(yin)素(su),線(xian)繞電機取0.65,異(yi)步(bu)電(dian)機取0.5。
lmax-zui大(da)負荷(he)電(dian)流(liu)
lmax=K起(lfa+lfb+lfc)lfa、lfb、lfc見(jian)前(qian)註釋
K起壹起(qi)動(dong)系(xi)數(shu),線(xian)繞電機取2,直流(liu)電機取2-2.5
(二(er))供電(dian)方式
當(dang)電壓降超(chao)過(guo)標(biao)準時,除選(xuan)用(yong)較(jiao)大(da)壹級(ji)截面導管外,可采用(yong)不同供電(dian)方式以(yi)改(gai)變(bian)計算長度L。



(三)熱(re)膨脹(zhang)補(bu)償的確定(ding)
1、室(shi)內安裝:全(quan)線(xian)長(chang)程在100m以(yi)內(nei),壹般(ban)不加熱膨脹(zhang)補(bu)償點,組(zu)裝時在導管接頭(tou)處(chu)需留間(jian)隙5mm。
2、室(shi)外安裝:線(xian)路(lu)超(chao)過(guo)100m以(yi)上(shang)慶(qing)考(kao)慮熱(re)膨脹補償點。
(1)間(jian)隙補(bu)償(chang)法:
原理:在(zai)導管連接處(chu)的相鄰(lin)導管間(jian)交錯(cuo)留有(you)間(jian)隙,供熱(re)膨(peng)脹(zhang)補(bu)償延伸(shen)之(zhi)用,補償(chang)點兩端應固定(ding)懸(xuan)吊,其余(yu)浮(fu)動(dong)懸吊。每段(duan)導管的補償(chang)間(jian)隙如下:
![]() | 熱膨(peng)脹補(bu)償(chang)表(biao)
| |||||||||||||||
熱(re)膨(peng)脹補償(chang)表(biao)
|
補償(chang)段(duan)確(que)定(ding):總(zong)長(chang)度超過(guo)100m的供電(dian)安(an)全(quan)滑(hua)觸(chu)線(xian),考(kao)慮到(dao)整(zheng)條(tiao)管路的熱膨(peng)脹變(bian)化,采用(yong)固定(ding)懸(xuan)吊與(yu)浮(fu)動(dong)懸吊兩(liang)種方式:兩(liang)固定(ding)懸(xuan)吊之(zhi)間(jian),稱(cheng)為補(bu)償段(duan),根據全(quan)年溫(wen)差,確(que)定(ding)補(bu)償(chang)兩(liang)側(ce)固定(ding)懸(xuan)吊的zui大(da)間(jian)距(ju)Lmax,壹般(ban)不少於(yu)12cm,固定(ding)懸(xuan)吊配置(zhi)見(jian)下圖(tu):


(2)分(fen)離(li)補償(chang)法
原理:在(zai)環(huan)境(jing)溫(wen)差較(jiao)大(da),運(yun)行速度不高(gao)的情況(kuang)下,可采用(yong)分(fen)離(li)補償(chang)法。導管在接頭(tou)處(chu)分(fen)離(li)壹段(duan)距(ju)離(li)作熱(re)膨脹補償之(zhi)用,導管分(fen)離(li)處(chu)均(jun)套(tao)上(shang)嗽(sou)叭導入(ru)管,分(fen)離(li)導管采取(qu)分(fen)別(bie)供電(dian)方式。

導電器由(you)彈(dan)簧(huang)托(tuo)架傳(chuan)動(dong),以(yi)保(bao)持(chi)其脫離(li)導管時的正(zheng)確(que)位(wei)置(zhi),為(wei)保(bao)證(zheng)連續(xu)供電(dian),必須采用(yong)雙極(ji)導電器。補(bu)償(chang)段設置(zhi):補(bu)償(chang)段(duan)位(wei)於(yu)兩(liang)固定(ding)懸(xuan)掛(gua)中(zhong)點位(wei)置(zhi),壹般(ban)間(jian)隔(ge)為(wei)500mm。


安裝要(yao)求(qiu)
a:分(fen)離(li)處(chu)兩端必須分(fen)別(bie)供電(dian),相(xiang)位(wei)必須*。
b:分(fen)離(li)導管兩端必須有嗽(sou)叭導入(ru)管。
c:分(fen)離(li)處(chu)導管應較(jiao)正(zheng)中(zhong)心(xin)線(xian),保(bao)持(chi)同軸度1mm。
d:彈簧(huang)托(tuo)架導電器其間(jian)隔(ge)距(ju)離(li)不小於(yu)550mm。
例(li):全(quan)年使(shi)用(yong)環(huan)境(jing)溫(wen)度-20°C-+55°C:安裝時環(huan)境(jing)溫(wen)度:T=18°C。試求(qiu)熱(re)補償間(jian)隙X。溫(wen)差△t=75°C補(bu)償(chang)間(jian)隙:
(四(si))檢(jian)修(xiu)段
1、原理和功(gong)能:當(dang)起重(zhong)設備進(jin)入(ru)檢(jian)修(xiu)段時,輸電導管工作(zuo)段仍能(neng)通電工(gong)作,檢(jian)修(xiu)段和工(gong)作段采取(qu)分(fen)別(bie)供電(dian)要(yao)求(qiu)相(xiang)位(wei)*,兩(liang)段連(lian)接處(chu)采用(yong)絕緣隔(ge)離(li),當(dang)需檢(jian)修(xiu)起重(zhong)機進(jin)入(ru)檢(jian)修(xiu)後,即(ji)可切(qie)斷(duan)檢(jian)修(xiu)段電(dian)源(yuan)。

2、型(xing)式
(1)連(lian)接式:在(zai)壹條(tiao)導管中(zhong),兩(liang)段(duan)導軌之(zhi)間(jian)用(yong)絕(jue)緣材料(liao)隔(ge)開。

(2)分(fen)離(li)式
七、安(an)裝要(yao)點
(壹)安(an)裝位(wei)置(zhi)選(xuan)擇
1、安裝位(wei)置(zhi)盡(jin)可能(neng)靠近(jin)移動(dong)受(shou)電設施同壹側(ce)
2、安裝位(wei)置(zhi)盡(jin)可能(neng)避開高(gao)溫熱(re)源(yuan),強光照射(she)及其紅、紫外(wai)線(xian)輻(fu)射(she)。
3、應保(bao)證(zheng)不受(shou)物體(ti)撞(zhuang)擊(ji)和便(bian)於(yu)日(ri)後維(wei)修(xiu)。
(二)支(zhi)架(jia)安(an)裝方式的確定(ding)
可由(you)廠方提供安(an)裝方式預(yu)約(yue)訂做。
(三)安(an)裝前(qian)的準備(bei)工作
1、根(gen)據(ju)地形和廠方要(yao)求(qiu)繪制安裝示(shi)意圖(tu)。無(wu)特(te)殊情(qing)況(kuang)可按(an)下圖(tu)進(jin)行準備(bei)工作。
2、支架(jia)裝配,直線(xian)導管每根(gen)長(chang)4m,支架(jia)的懸吊間(jian)距(ju)按(an)下圖(tu)進(jin)行安裝,亦可根(gen)據現(xian)場(chang)環(huan)境(jing)條(tiao)件(jian)增(zeng)減支(zhi)架的間(jian)距(ju)。支(zhi)架必須牢固且(qie)排(pai)列整(zheng)齊(qi)美(mei)觀(guan)。
3、安裝檢(jian)查(zha)
(1)檢(jian)查(zha)導管外有(you)無(wu)破(po)裂、扭曲變形,導管內導軌接頭(tou)是否(fou)平直光滑。
(2)導電器應靈(ling)活(huo)自(zi)如的通過(guo)導管。
(3)導電器內(nei)電(dian)刷應伸(shen)縮(suo)自如,完整(zheng)無(wu)缺(que)、且(qie)有(you)壹定(ding)彈(dan)性。





(四(si))安裝導管
1、根據(ju)安裝示(shi)意圖(tu),將(jiang)導管、熱膨(peng)脹補(bu)償管、檢(jian)修(xiu)導管、中(zhong)間(jian)供電(dian)段(duan)導管執著示(shi)意圖(tu)位(wei)置(zhi)順(shun)序(xu)排好(hao),以(yi)利(li)工作順利(li)開展。
2、定(ding)形夾(jia)和懸(xuan)吊夾(jia)可預(yu)先安裝在每根(gen)導管上,在(zai)吊裝時再調(tiao)懸吊夾(jia)的抽向(xiang)位(wei)置(zhi),並(bing)調(tiao)導管與(yu)受(shou)電機械的運動(dong)軌道(dao)平行。在懸(xuan)吊架(jia)處(chu)測(ce)量水平高(gao)度允(yun)差為(wei)2mm,水平距離(li)允(yun)差4mm。
3、導軌連(lian)接,有(you)折(zhe)角(jiao)連接及(ji)對(dui)接兩(liang)種型(xing)式。接頭(tou)螺(luo)釘必須旋緊(jin),防止(zhi)松動(dong),以(yi)免(mian)在通過(guo)電流(liu)時產(chan)生(sheng)過(guo)熱現(xian)象(xiang);導軌內(nei)側(ce)表(biao)面必須對合在同壹平面內(nei),使(shi)過(guo)渡平滑,將(jiang)導電器在(zai)接頭(tou)處(chu)反復(fu)推行時應無(wu)撞(zhuang)阻(zu)礙(ai)感(gan)覺,必要(yao)時可用(yong)細銼(cuo)刀(dao)修(xiu)整(zheng)至(zhi)圓(yuan)滑過(guo)渡。導軌的連接重(zhong)量是滑觸(chu)線(xian)安(an)裝質量的關鍵,必須認(ren)真(zhen)操作。
4、導管連接采用(yong)連接夾(jia),連接夾(jia)的下沿嵌入(ru)導管槽(cao)內(nei),以(yi)保(bao)證(zheng)兩導管對接同軸度。
5、安裝端部或(huo)中(zhong)間(jian)進(jin)線(xian)盒(he)衣(yi)端蓋,端部進(jin)線(xian)盒(he)及(ji)雕(diao)蓋均(jun)應以(yi)螺(luo)釘固定(ding)。
6、安(an)裝撥叉(cha),撥(bo)叉(cha)可焊(han)接或(huo)用螺(luo)栓固定(ding)在(zai)傳(chuan)動(dong)臂(bi)上,傳(chuan)動(dong)臂(bi)安裝於(yu)導電器設施上,其表(biao)面與(yu)導管中(zhong)心(xin)zui近(jin)距離(li)應保(bao)持(chi)在(zai)100mm左右。撥叉(cha)插入(ru)導電器內(nei),應保(bao)證(zheng)在全(quan)線(xian)自(zi)由(you)上下擺(bai)動(dong)。其範圍(wei)為(wei)40mm,並(bing)能(neng)吸(xi)收(shou)其它方向(xiang)的傳動(dong)誤差和沖(chong)擊(ji)。
7、接通電源(yuan)試(shi)行時應註(zhu)意下列事(shi)項(xiang):
(1)通電前(qian)復查(zha)全(quan)線(xian)安(an)裝情況,確認(ren)無(wu)誤(wu)後,調(tiao)試(shi)人員(yuan)可進(jin)行入(ru)操作崗(gang)位(wei),其他(ta)人員(yuan)應撤(che)離(li)現(xian)場(chang)或(huo)進(jin)入(ru)安全(quan)地區。
(2)接通電源(yuan)後,不急於(yu)開動(dong)起重(zhong)機,觀察(cha)靜(jing)態(tai)通電是否(fou)正(zheng)常(chang),然後啟動(dong)小車(che)電機,試運(yun)行兩分(fen)種,再(zai)啟動(dong)大(da)天(tian)車(che)電(dian)機,以(yi)低(di)速行駛(shi),沿全(quan)線(xian)觀(guan)察(cha),應特(te)別(bie)註(zhu)意(yi)運動(dong)部分(fen)與(yu)支(zhi)架、水泥(ni)柱(zhu)等有(you)無(wu)碰(peng)擦的可能(neng)性,若(ruo)發(fa)現(xian)下述情(qing)況,應立(li)即(ji)糾(jiu)正(zheng):
a、導管有較(jiao)大(da)異(yi)動(dong),應調(tiao)整(zheng)導管或(huo)修(xiu)正(zheng)撥(bo)叉(cha)。
b、導電器運(yun)行時有異(yi)常(chang)聲(sheng)響(xiang),應檢(jian)查(zha)導軌連(lian)接點是否(fou)平坦。
八、維(wei)護保(bao)養及故(gu)障(zhang)處(chu)理
(壹)維(wei)護(hu)保(bao)養
供電(dian)滑(hua)觸(chu)線(xian)在(zai)正(zheng)常(chang)使(shi)用(yong)階段(duan),應定(ding)期(qi)檢(jian)查(zha)下列有(you)關部(bu)件(jian):
1、檢(jian)查(zha)導管內導電器的電刷(shua)磨損(sun)情況(kuang),如已超過(guo)正(zheng)常(chang)磨損(sun)長度要(yao)入(ru)時更換(huan)。
2、檢(jian)查(zha)導管(軌)接頭(tou),有(you)無(wu)銹蝕(shi)與(yu)松動(dong)。各固定(ding)增(zeng)值(zhi),撥叉(cha)等(deng)是否(fou)松動(dong)。
3、檢(jian)查(zha)導管是否(fou)彎曲變形。
4、清除導管上積(ji)累的灰(hui)塵(chen),清掃(sao)時不可用(yong)力過(guo)大(da),以(yi)防(fang)損(sun)壞(huai)塑料(liao)導管。
5、導電器中(zhong)電(dian)刷(shua)磨情況(kuang),當(dang)電刷(shua)磨損(sun)到距(ju)離(li)其極(ji)限伸(shen)出位(wei)置(zhi)小(xiao)於(yu)2mm時應立(li)即(ji)更換(huan)新的電刷(shua)。
6、檢(jian)查(zha)滾(gun)輪(lun)磨損(sun)狀況(kuang),滾(gun)輪(lun)能確(que)保(bao)電(dian)刷(shua)在(zai)導管上下左右的正(zheng)確(que)位(wei)置(zhi),滾(gun)輪(lun)磨損(sun)過(guo)度,亦會(hui)造(zao)成電(dian)刷磨損(sun)或(huo)繼續失(shi)電現(xian)象(xiang)發(fa)生(sheng)。
(二(er))故(gu)障(zhang)處(chu)理
| 故(gu)障(zhang)現(xian)象(xiang) | 故(gu)障(zhang)原因(yin) | 處(chu)理方法 |
| 斷(duan)電現(xian)象(xiang) | 1、電(dian)刷在導管中(zhong)爬(pa)坡(po) 2、電(dian)刷磨損(sun)已超(chao)過(guo)有效長(chang)度 3、導管接頭(tou)高(gao)低不平 4、單(dan)導電器 5、導軌連(lian)接不好(松動(dong)) | 1、輕(qing)輕(qing)搖(yao)動(dong)導電器或(huo)導管、檢(jian)查(zha)導電器滾(gun)輪(lun)磨損(sun)情況(kuang),更(geng)換(huan)滾輪(lun)或(huo)導電器 |
| 導管明(ming)顯變形造(zao)成導電器無(wu)法移動(dong) | 1、環(huan)境(jing)局部溫(wen)度過(guo)高(gao) 2、定(ding)形夾(jia)間(jian)距(ju)過(guo)大(da)或(huo)松脫 3、浮(fu)動(dong)懸吊夾(jia)卡死導管熱膨(peng)脹無(wu)法延伸(shen) 4、缺少熱(re)膨(peng)脹(zhang)補償節(jie) | 1、采用(yong)隔(ge)熱(re)板(ban),室(shi)外應裝遮(zhe)陽(yang)板(ban) 2、增(zeng)加定(ding)形夾(jia),並(bing)進(jin)行校(xiao)正(zheng) 3、調(tiao)節浮(fu)動(dong)懸吊夾(jia),使(shi)導管能自(zi)由延伸(shen) 4、增加熱膨脹(zhang)補(bu)償段(duan)(點) |
| 工作(zuo)時導管晃(huang)動(dong)太大(da) | 1、撥(bo)叉(cha)未吸收(shou)傳動(dong)誤差 2、安(an)裝導管直線(xian)度不好 3、定(ding)形夾(jia)松動(dong) | 1、修(xiu)正(zheng)撥(bo)叉(cha),增(zeng)加各自由(you)度,吸收(shou)誤(wu)差環(huan)節 2、校(xiao)正(zheng)導管的直線(xian)度 3、擰緊(jin)定(ding)形夾(jia)螺栓 |
| 電(dian)刷磨損(sun)太快(kuai) | 1、接頭(tou)不平整(zheng) 2、載流(liu)量過(guo)大(da),電(dian)弧(hu)灼傷(shang) 3、彈簧(huang)壓力太(tai)大(da) | 1、按(an)要(yao)求(qiu)重(zhong)新連接導軌 2、增(zeng)加導電器在(zai)數(shu)量 3、減少(shao)彈簧(huang)壓力 |
| 電(dian)刷(shua)側(ce)面擦傷(shang)和表(biao)面有(you)粒(li)凹坑(keng) | 1、導電器在(zai)導管內定(ding)位(wei)不好,滾(gun)輪(lun)磨損(sun),撥叉(cha)傳(chuan)遞(di)側(ce)向(xiang)力大(da) 2、電(dian)刷(shua)與(yu)導管接觸(chu)不良(liang)產(chan)生(sheng)火(huo)花(hua)灼傷(shang) 3、電流(liu)過(guo)大(da) | 1、更(geng)換(huan)液(ye)輪(lun)或(huo)導電器更(geng)換(huan)撥叉(cha) 2、檢(jian)查(zha)導軌接頭(tou),使(shi)平整(zheng)光滑,使(shi)電(dian)刷與(yu)導軌接觸(chu)面(mian)積60-90%,增加導電器數(shu)量 |
| 導電器滑(hua)行有較(jiao)大(da)聲(sheng)音(yin) | 1、接頭(tou)不平整(zheng) | 1、按(an)接頭(tou)工(gong)藝要(yao)求(qiu),重(zhong)新處(chu)理 |
| 導電器外(wai)殼(ke)有擦痕 | 1、導管變形 2、導電器在(zai)定(ding)位(wei)不好 | 1、導管開口(kou)尺(chi)寸(cun),狹窄(zhai),應撬(qiao)大(da)槽(cao)口(kou)或(huo)增加定(ding)形夾(jia) 2、更換(huan)導電器滾(gun)輪(lun) |
九、訂(ding)貨(huo)和儲(chu)運(yun)
(壹)訂(ding)貨(huo):用戶(hu)在(zai)填(tian)寫(xie)訂(ding)貨(huo)單(dan)時,應詳細寫明(ming)單(dan)位(wei)名(ming)稱(cheng)、地址(zhi)及(ji)所(suo)需供電(dian)滑(hua)觸(chu)線(xian)型(xing)號(hao)、規格、數量等(deng)有(you)關事(shi)項(xiang)。
(二)儲(chu)運(yun)及儲(chu)存(cun):供電(dian)滑(hua)觸(chu)線(xian)主(zhu)、副(fu)件分(fen)別(bie)裝箱(xiang),對(dui)於(yu)易(yi)撣損(sun)的零(ling)部件(jian),有妨震材(cai)料(liao)隔(ge)離(li)旋轉(zhuan)但(dan)仍應註(zhu)意防止(zhi)劇(ju)烈碰(peng)撞(zhuang)或(huo)倒(dao)置(zhi),以(yi)免(mian)損(sun)壞(huai)。供電(dian)滑(hua)觸(chu)線(xian)運(yun)抵單(dan)位(wei),暫(zan)時不安裝者(zhe),其儲(chu)存(cun)庫記具(ju)備良(liang)好(hao)的通風、幹(gan)燥(zao),盡可能(neng)避開高(gao)溫、熱(re)源(yuan)和高(gao)濕度的地方。
|
|
| ||||||||||||||||||||||||
|
|
| ||||||||||||||||||||||||
|
|
|
: