多極管(guan)式(shi)滑觸線產(chan)品組件說(shuo)明
(壹(yi))供(gong)電導(dao)管(guan):承(cheng)載(zai)電源導(dao)入的電流輸送到導(dao)電器,每(mei)根(gen)導(dao)管(guan)長(chang)為(wei)4M,亦(yi)可(ke)根(gen)據需方要(yao)求(qiu)訂做,規格參閱表3-1
(二)導(dao)電器:在(zai)導(dao)管(guan)內(nei)與導(dao)軌(gui)滑動(dong)接觸導(dao)入電流,並(bing)向(xiang)其(qi)它移動(dong)式(shi)電器提(ti)供(gong)電流的裝(zhuang)置(zhi)(見(jian)圖5-1)。

(三(san))中(zhong)間(jian)進(jin)線盒:由導(dao)管(guan)的中(zhong)部導(dao)入電源電流的裝(zhuang)置(zhi)(圖5-2)
(四)端部(bu)進線盒:由導(dao)管(guan)的頂(ding)端導(dao)入電源電流的裝(zhuang)置(zhi)(圖5-3)

(五(wu))連(lian)接夾(jia):位於(yu)相鄰兩導(dao)管(guan)連(lian)接處,作連(lian)接固(gu)定(ding)和(he)絕緣(圖5-4)
(六(liu))定形(xing)夾(jia):保持導(dao)管(guan)不(bu)變(bian)形(圖5-5、5-6)

(七(qi))撥(bo)叉:向(xiang)導(dao)電器傳(chuan)遞移動(dong)推力或拉(la)力,並(bing)適(shi)度(du)吸收傳(chuan)動(dong)誤(wu)差(cha)和(he)傳動(dong)沖(chong)擊(ji),撥(bo)叉可(ke)根(gen)據導(dao)電器數(shu)量(liang)和型(xing)號配用(圖5-7)
(八(ba))室(shi)外安全(quan)滑(hua)觸線地溝(gou)結(jie)構



六(liu)、選(xuan)用(yong)產(chan)品應(ying)註意事項(xiang)
(壹(yi))導(dao)管(guan)選(xuan)用(yong)
1、查(zha)表法(fa):根(gen)據負(fu)載(zai)配(pei)置(zhi)總(zong)功率,負(fu)載(zai)持續率、使用環境(jing)、起(qi)重機(ji)械(xie)噸位(wei)及(ji)其(qi)額定工(gong)作電流,查表3-1或表6-1確定導(dao)管(guan)規格。
2、功率估算(suan)法(fa)
(1)根(gen)據負(fu)載(zai)特(te)點(dian)、估算(suan)負(fu)載(zai)總(zong)功率Σp
a.n負(fu)載(zai)同(tong)時(shi)工(gong)作:Σp=Pa+Pb+...+Pn
b.n個(ge)負(fu)載(zai)不(bu)同(tong)時(shi)工(gong)作:Σp=pa+pb+pc...
其(qi)中(zhong):pazui大(da)壹(yi)個(ge)負(fu)載(zai)功率;pb、pc其(qi)余(yu)二(er)個(ge)可(ke)能(neng)同(tong)時(shi)動(dong)作的負(fu)載(zai)功率。
(2)根(gen)據下(xia)表查供(gong)電滑觸線導(dao)管(guan)承(cheng)載(zai)線三(san)相交流功率PN保證PN>Σp
負(fu)載(zai)持續率和許(xu)用(yong)環境(jing)溫(wen)以(yi)系(xi)數Kt和(he)Kε進行(xing)修(xiu)正。
吊車功率——導(dao)管(guan)軌(gui)道截(jie)面速查(zha)表
| 吊車類型(xing) | 起(qi)重量(liang)(t) | 額定總(zong)功率(KW) | 電動(dong)機功率 | 額定負(fu)載(zai)持續率 ε=25% | 額定負(fu)載(zai)持續率ε=40% | ||||||
| 主鉤(gou)(KW/A) | 副(fu)鉤(gou)(KW/A) | 大(da)車(KW/A) | 小車(KW/A) | 計(ji)算(suan)電流|(A) | 導(dao)線 截面BBLX mm2 | 導(dao)管(guan)軌(gui)道截(jie)面 mm2 | 計(ji)算(suan)電流|(A) | 40°C時(shi)導(dao)管(guan)軌(gui)道截(jie)面mm2 | |||
| 電 動(dong) 葫(hu) 蘆(lu) | 0.5 | 1.1 | 0.8/3 | 0.3/0.9 | 3 | 2.5 | 10 | 10 | |||
| 1 | 2.8 | 2.2/6.4 | 0.6/1.9 | 6.4 | 2.5 | 10 | 10 | ||||
| 2 | 4.1 | 3.5/9.2 | 0.6/1.9 | 9.2 | 2.5 | 10 | 10 | ||||
| 3 | 6 | 5/13 | 1/2.9 | 9.2 | 2.5 | 10 | 10 | ||||
| 5 | 8.5 | 7.5/19.7 | 1/2.9 | 19.2 | 4 | 10 | 10 | ||||
| 梁 式(shi) 吊 車 | 0.5 | 3.3 | 0.8/3 | 2.5/5 | 0.3/0.9 | 5 | 2.5 | 10 | 10 | ||
| 1 | 5 | 2.2/6.4 | 2.5/5 | 0.6/1.9 | 6.4 | 2.5 | 10 | 10 | |||
| 2 | 6.3 | 3.5/9.2 | 2.2/5 | 0.6/1.9 | 9.2 | 2.5 | 10 | 10 | |||
| 3 | 8.9 | 5/13 | 2.2/5 | 1.7/3.7 | 13 | 2.5 | 10 | 10 | |||
| 5 | 11.4 | 7.5/19.7 | 2.2/5 | 1.7/3.7 | 19.7 | 4 | 10 | 10 | |||
| 橋 式(shi) 吊 車 | 5 | 23.2 | 11/28 | 2.2/7.2 | 27.5 | 6 | 16 | 41 | 16 | ||
| 10 | 29.5 | 16/43 | 3.5/10 | 35 | 10 | 16 | 58 | 25 | |||
| 15/3 | 35.5 | 22/57 | 11/31 | 3.5/10 | 42 | 16 | 25 | 103 | 35 | ||
| 20/5 | 48.5 | 30/72 | 16/43 | 3.5/10 | 58 | 25 | 25 | 103 | 35 | ||
| 30/5 | 80 | 60/133 | 16/43 | 5/15 | 94 | 50 | 35 | 140 | 50 | ||
| 50/10 | 89.5 | 60/133 | 30/80 | 7.5/21 | 105 | 50 | 50 | 156 | 70 | ||
導(dao)管(guan)截(jie)流量修(xiu)正系(xi)數
| 溫(wen)度(du)°C | 25 | 30 | 35 | 40 | 50 | 55 | 60 |
| Kt溫(wen) | 1 | 0.94 | 0.89 | 0.82 | 0.67 | 0.53 | 0.47 |
接(jie)電持續率修正系(xi)數表
| ε % | 100 | 60 | 40 | 25 | 15 | 10 |
| Kε接 | 1 | 1.24 | 1.47 | 1.85 | 2.35 | 2.85 |
3、電流估算(suan)法(fa)
(1)工(gong)作電流If估算(suan):按負(fu)載(zai)的額定工(gong)作電流選(xuan)用(yong)導(dao)管(guan),當工(gong)作溫(wen)度(du)為(wei)40°C,壹(yi)般起(qi)重機(ji);
If-Ifa+Ifb+Ifc
Ifa-zui大(da)功率電機折(zhe)算(suan)或負(fu)載(zai)持續率。
Jc=100%時(shi)的工作電流
Ifb、Ifc-其(qi)余(yu)可(ke)能(neng)同(tong)時(shi)動(dong)作二只電機,Ic=100%時(shi)折(zhe)算(suan)工(gong)作電流。對(dui)於(yu)大(da)容(rong)量(liang)、多電機起(qi)重機(ji)、由(you)下(xia)列(lie)經驗(yan)公式(shi)計(ji)算(suan)。
If=Kalc+KbΣ |+A
其(qi)中(zhong):Ic-起(qi)重機(ji)其(qi)余(yu)電機總(zong)電流(Jc=25%時(shi))
Σ i-起(qi)重機(ji)其(qi)余(yu)電機總(zong)電流(Jc=25%時(shi))
A-其(qi)它負(fu)載(zai)工(gong)作電流壹(yi)般取(qu)10(A)
Ka、Kb-功率電流轉(zhuan)換系(xi)數表
| 電流、系(xi)數、起(qi)重機(ji)類別(bie) | 輕極(ji)(M4) | 中(zhong)級(M5) | 重機(ji)(M6) | 特(te)重機(ji)(M7) | |
| 交流380V | Ka | 0.6 | 0.6 | 0.9 | 0.9 |
| Kb | 0.2 | 0.3 | 0.4 | 0.6 | |
| 直流220V | Ka | 1.2 | 1.2 | 1.8 | 1.8 |
| Kb | 0.4 | 0.6 | 0.8 | 1.2 | |
(2)查(zha)《吊車功率—導(dao)管(guan)軌(gui)道截(jie)面速查(zha)表》確定選(xuan)用(yong)規格,保證IN>1f
IN——導(dao)管(guan)35°C時(shi)連(lian)續載(zai)流量
4、電壓(ya)降(jiang)校核:長(chang)度(du)在(zai)100m以(yi)內(nei)的導(dao)管(guan)按功率或電流估算(suan)法(fa)選(xuan)用(yong)後(hou),可(ke)不(bu)進(jin)行(xing)電壓(ya)降(jiang)校核。
(1)電壓(ya)降(jiang)△U≈指(zhi)標(biao):壹(yi)般起(qi)重機(ji)△U<7%,治(zhi)金起(qi)重機(ji)△U<5%,其(qi)它用(yong)電設施(shi)根(gen)據產(chan)品標(biao)準(zhun)要(yao)求(qiu)。
(2)校核方法(fa):三(san)相交流負(fu)載(zai):
△U≈173lmaxLcosψ % 直(zhi)流負(fu)載(zai): △U≈200lmaxL %
δSUn δSUn
其(qi)中(zhong)L-供電滑觸線裝(zhuang)置(zhi)計(ji)算(suan)長(chang)度m(見(jian)供電方式(shi))。
δ-導(dao)電率,銅取(qu)50m/Ωmm2
S-導(dao)軌(gui)截面積mm2
Un-額定工(gong)作電壓(ya)
COSψ-功率因素(su),線繞電機取(qu)0.65,異步電機取(qu)0.5。
lmax-zui大(da)負(fu)荷電流
lmax=K起(qi)(lfa+lfb+lfc)lfa、lfb、lfc見(jian)前(qian)註(zhu)釋(shi)
K起(qi)壹(yi)起(qi)動(dong)系(xi)數,線繞電機取(qu)2,直(zhi)流電機取(qu)2-2.5
(二(er))供(gong)電方式(shi)
當電壓(ya)降(jiang)超(chao)過標(biao)準(zhun)時(shi),除(chu)選(xuan)用(yong)較(jiao)大(da)壹(yi)級(ji)截(jie)面導(dao)管(guan)外(wai),可(ke)采(cai)用(yong)不(bu)同(tong)供電方式(shi)以(yi)改(gai)變(bian)計(ji)算(suan)長(chang)度L。



(三(san))熱(re)膨(peng)脹(zhang)補(bu)償的確定
1、室(shi)內安裝(zhuang):全(quan)線長程(cheng)在(zai)100m以(yi)內(nei),壹(yi)般不(bu)加熱(re)膨(peng)脹(zhang)補(bu)償點,組裝(zhuang)時(shi)在(zai)導(dao)管(guan)接(jie)頭(tou)處需留間(jian)隙5mm。
2、室(shi)外安裝(zhuang):線路超(chao)過100m以(yi)上(shang)慶(qing)考慮(lv)熱(re)膨(peng)脹(zhang)補(bu)償點。
(1)間(jian)隙補(bu)償法(fa):
原(yuan)理(li):在(zai)導(dao)管(guan)連(lian)接處的相鄰導(dao)管(guan)間(jian)交錯(cuo)留有間(jian)隙,供熱(re)膨(peng)脹(zhang)補(bu)償延(yan)伸之用(yong),補(bu)償點兩端應(ying)固定(ding)懸(xuan)吊,其(qi)余(yu)浮(fu)動(dong)懸吊。每(mei)段(duan)導(dao)管(guan)的補(bu)償間(jian)隙如(ru)下(xia):
![]() | 熱(re)膨(peng)脹(zhang)補(bu)償表
| |||||||||||||||
熱(re)膨(peng)脹(zhang)補(bu)償表
|
補(bu)償段(duan)確定:總(zong)長(chang)度(du)超(chao)過100m的供電安全(quan)滑(hua)觸線,考慮(lv)到整條(tiao)管(guan)路的熱(re)膨(peng)脹(zhang)變(bian)化,采(cai)用(yong)固(gu)定(ding)懸吊與浮動(dong)懸吊兩(liang)種(zhong)方式(shi):兩固(gu)定懸吊之間(jian),稱(cheng)為(wei)補(bu)償段(duan),根(gen)據全(quan)年(nian)溫(wen)差(cha),確定補(bu)償兩側(ce)固定(ding)懸吊的zui大(da)間(jian)距(ju)Lmax,壹(yi)般不(bu)少(shao)於(yu)12cm,固(gu)定(ding)懸(xuan)吊配(pei)置(zhi)見下(xia)圖:


(2)分(fen)離(li)補(bu)償法(fa)
原(yuan)理(li):在(zai)環境(jing)溫(wen)差(cha)較(jiao)大(da),運(yun)行(xing)速度(du)不(bu)高的情況(kuang)下(xia),可(ke)采(cai)用(yong)分(fen)離(li)補(bu)償法(fa)。導(dao)管(guan)在(zai)接頭(tou)處分(fen)離(li)壹(yi)段(duan)距(ju)離(li)作熱(re)膨(peng)脹(zhang)補(bu)償之用(yong),導(dao)管(guan)分(fen)離(li)處均套上嗽(sou)叭(ba)導(dao)入管(guan),分(fen)離(li)導(dao)管(guan)采(cai)取(qu)分(fen)別(bie)供電方式(shi)。

導(dao)電器由(you)彈(dan)簧(huang)托架(jia)傳(chuan)動(dong),以(yi)保(bao)持其(qi)脫離(li)導(dao)管(guan)時(shi)的正確位置(zhi),為(wei)保(bao)證連(lian)續供電,必須(xu)采(cai)用(yong)雙極導(dao)電器。補(bu)償段(duan)設(she)置(zhi):補(bu)償段(duan)位(wei)於(yu)兩(liang)固(gu)定(ding)懸(xuan)掛中(zhong)點位置(zhi),壹(yi)般間(jian)隔(ge)為(wei)500mm。


安裝(zhuang)要(yao)求(qiu)
a:分(fen)離(li)處兩端(duan)必須(xu)分(fen)別(bie)供電,相位(wei)必須(xu)*。
b:分(fen)離(li)導(dao)管(guan)兩(liang)端(duan)必須(xu)有嗽(sou)叭(ba)導(dao)入管(guan)。
c:分(fen)離(li)處導(dao)管(guan)應(ying)較(jiao)正(zheng)中(zhong)心(xin)線,保持同(tong)軸度1mm。
d:彈(dan)簧(huang)托架(jia)導(dao)電器其(qi)間(jian)隔(ge)距(ju)離(li)不(bu)小(xiao)於(yu)550mm。
例(li):全(quan)年(nian)使用環境(jing)溫(wen)度(du)-20°C-+55°C:安裝(zhuang)時(shi)環境(jing)溫(wen)度(du):T=18°C。試(shi)求熱(re)補(bu)償間(jian)隙X。溫(wen)差(cha)△t=75°C補(bu)償間(jian)隙:
(四)檢修段(duan)
1、原(yuan)理(li)和(he)功能(neng):當起(qi)重設(she)備進入(ru)檢修段(duan)時(shi),輸電導(dao)管(guan)工(gong)作段(duan)仍(reng)能(neng)通電工作,檢修段(duan)和(he)工(gong)作段(duan)采(cai)取(qu)分(fen)別(bie)供電要(yao)求(qiu)相位(wei)*,兩段(duan)連(lian)接處采(cai)用(yong)絕(jue)緣(yuan)隔(ge)離(li),當需檢修起(qi)重機(ji)進(jin)入檢修後,即可(ke)切斷檢修段(duan)電源。

2、型(xing)式(shi)
(1)連(lian)接式(shi):在(zai)壹(yi)條(tiao)導(dao)管(guan)中(zhong),兩段(duan)導(dao)軌(gui)之間(jian)用(yong)絕(jue)緣(yuan)材(cai)料(liao)隔(ge)開(kai)。

(2)分(fen)離(li)式(shi)
七(qi)、安裝(zhuang)要(yao)點(dian)
(壹(yi))安裝(zhuang)位(wei)置(zhi)選(xuan)擇(ze)
1、安裝(zhuang)位(wei)置(zhi)盡可(ke)能(neng)靠(kao)近移動(dong)受電設施(shi)同(tong)壹(yi)側(ce)
2、安裝(zhuang)位(wei)置(zhi)盡可(ke)能(neng)避開(kai)高溫(wen)熱(re)源,強(qiang)光(guang)照(zhao)射(she)及(ji)其(qi)紅、紫(zi)外(wai)線輻射。
3、應(ying)保證不(bu)受(shou)物(wu)體(ti)撞(zhuang)擊(ji)和便(bian)於(yu)日後(hou)維修(xiu)。
(二(er))支(zhi)架(jia)安裝(zhuang)方式(shi)的確定
可(ke)由廠方提(ti)供(gong)安裝(zhuang)方式(shi)預(yu)約(yue)訂(ding)做。
(三(san))安裝(zhuang)前(qian)的準備工作
1、根(gen)據地形(xing)和(he)廠方要(yao)求(qiu)繪(hui)制(zhi)安裝(zhuang)示(shi)意圖。無(wu)特(te)殊情況(kuang)可(ke)按下(xia)圖進行(xing)準(zhun)備工作。
2、支(zhi)架(jia)裝(zhuang)配(pei),直(zhi)線導(dao)管(guan)每(mei)根(gen)長(chang)4m,支(zhi)架(jia)的懸吊間(jian)距(ju)按下(xia)圖進行(xing)安裝(zhuang),亦(yi)可(ke)根(gen)據現場(chang)環境(jing)條(tiao)件增(zeng)減(jian)支(zhi)架(jia)的間(jian)距(ju)。支(zhi)架(jia)必須(xu)牢(lao)固且(qie)排列(lie)整齊(qi)美觀。
3、安裝(zhuang)檢查
(1)檢查導(dao)管(guan)外(wai)有無(wu)破(po)裂(lie)、扭(niu)曲(qu)變(bian)形,導(dao)管(guan)內(nei)導(dao)軌(gui)接頭(tou)是(shi)否(fou)平(ping)直光(guang)滑。
(2)導(dao)電器應(ying)靈活(huo)自如(ru)的通過導(dao)管(guan)。
(3)導(dao)電器內(nei)電刷應(ying)伸縮(suo)自如(ru),完整(zheng)無(wu)缺、且(qie)有壹(yi)定(ding)彈(dan)性(xing)。





(四(si))安裝(zhuang)導(dao)管(guan)
1、根(gen)據安裝(zhuang)示(shi)意圖,將導(dao)管(guan)、熱(re)膨(peng)脹(zhang)補(bu)償管(guan)、檢修導(dao)管(guan)、中(zhong)間(jian)供(gong)電段(duan)導(dao)管(guan)執(zhi)著示(shi)意圖位置順(shun)序(xu)排好(hao),以(yi)利(li)工(gong)作順(shun)利(li)開(kai)展(zhan)。
2、定形夾(jia)和懸(xuan)吊夾(jia)可(ke)預(yu)先安裝(zhuang)在(zai)每根(gen)導(dao)管(guan)上(shang),在(zai)吊裝(zhuang)時(shi)再調懸吊夾(jia)的抽(chou)向(xiang)位(wei)置(zhi),並(bing)調導(dao)管(guan)與受電機械(xie)的運(yun)動(dong)軌(gui)道平(ping)行(xing)。在(zai)懸吊架(jia)處測量(liang)水(shui)平(ping)高度允差為(wei)2mm,水(shui)平(ping)距(ju)離(li)允(yun)差(cha)4mm。
3、導(dao)軌(gui)連(lian)接,有折(zhe)角(jiao)連(lian)接及(ji)對(dui)接兩種型(xing)式(shi)。接頭(tou)螺(luo)釘(ding)必須(xu)旋(xuan)緊,防(fang)止松(song)動(dong),以(yi)免(mian)在(zai)通過電流時(shi)產(chan)生(sheng)過熱(re)現象;導(dao)軌(gui)內側(ce)表面必須(xu)對(dui)合在(zai)同(tong)壹(yi)平(ping)面內,使過渡平(ping)滑,將導(dao)電器在(zai)接頭(tou)處反復推行(xing)時(shi)應(ying)無(wu)撞(zhuang)阻(zu)礙(ai)感(gan)覺,必要(yao)時(shi)可(ke)用細銼(cuo)刀修(xiu)整至圓滑(hua)過渡。導(dao)軌(gui)的連(lian)接重量(liang)是(shi)滑觸線安裝(zhuang)質(zhi)量(liang)的關鍵(jian),必須(xu)認(ren)真(zhen)操(cao)作。
4、導(dao)管(guan)連(lian)接采(cai)用(yong)連(lian)接夾(jia),連(lian)接夾(jia)的下(xia)沿(yan)嵌入導(dao)管(guan)槽內,以(yi)保(bao)證兩(liang)導(dao)管(guan)對(dui)接同(tong)軸度。
5、安裝(zhuang)端(duan)部(bu)或中(zhong)間(jian)進(jin)線盒衣端(duan)蓋,端部進線盒及(ji)雕蓋均應(ying)以(yi)螺(luo)釘(ding)固定。
6、安裝(zhuang)撥(bo)叉,撥(bo)叉可(ke)焊接或用螺(luo)栓(shuan)固(gu)定(ding)在(zai)傳動(dong)臂上(shang),傳動(dong)臂安裝(zhuang)於(yu)導(dao)電器設(she)施(shi)上,其(qi)表面與導(dao)管(guan)中(zhong)心(xin)zui近距(ju)離(li)應(ying)保持在(zai)100mm左右。撥(bo)叉插入(ru)導(dao)電器內(nei),應(ying)保證在(zai)全(quan)線自由(you)上(shang)下(xia)擺動(dong)。其(qi)範圍為(wei)40mm,並(bing)能(neng)吸收其(qi)它方向(xiang)的傳動(dong)誤(wu)差(cha)和(he)沖(chong)擊(ji)。
7、接(jie)通電源試(shi)行(xing)時(shi)應(ying)註意下(xia)列(lie)事項(xiang):
(1)通電前(qian)復查全(quan)線安裝(zhuang)情(qing)況(kuang),確認(ren)無(wu)誤(wu)後(hou),調試人(ren)員(yuan)可(ke)進行(xing)入(ru)操(cao)作崗(gang)位,其(qi)他人(ren)員(yuan)應(ying)撤離(li)現場(chang)或進入安全(quan)地區(qu)。
(2)接(jie)通電源後(hou),不(bu)急(ji)於(yu)開(kai)動(dong)起(qi)重機(ji),觀察靜(jing)態(tai)通電是否(fou)正(zheng)常,然後啟動(dong)小車電機,試(shi)運(yun)行(xing)兩(liang)分(fen)種(zhong),再啟動(dong)大(da)天(tian)車電機,以(yi)低速行(xing)駛,沿(yan)全(quan)線觀察,應(ying)特(te)別(bie)註意運(yun)動(dong)部分(fen)與支(zhi)架(jia)、水(shui)泥柱(zhu)等有無(wu)碰(peng)擦的可(ke)能(neng)性(xing),若(ruo)發現下(xia)述(shu)情(qing)況,應(ying)立即(ji)糾(jiu)正(zheng):
a、導(dao)管(guan)有較(jiao)大(da)異動(dong),應(ying)調整導(dao)管(guan)或修正撥(bo)叉。
b、導(dao)電器運(yun)行(xing)時(shi)有異常(chang)聲(sheng)響,應(ying)檢查導(dao)軌(gui)連(lian)接點(dian)是(shi)否(fou)平(ping)坦。
八(ba)、維護(hu)保(bao)養(yang)及(ji)故(gu)障(zhang)處理
(壹(yi))維(wei)護(hu)保(bao)養(yang)
供電滑觸線在(zai)正常(chang)使用階(jie)段(duan),應(ying)定期(qi)檢查下(xia)列(lie)有關(guan)部件:
1、檢查導(dao)管(guan)內(nei)導(dao)電器的電刷磨(mo)損情況,如(ru)已超(chao)過正(zheng)常磨(mo)損長度要(yao)入(ru)時(shi)更(geng)換。
2、檢查導(dao)管(guan)(軌(gui))接頭(tou),有無(wu)銹蝕與松(song)動(dong)。各固(gu)定增(zeng)值(zhi),撥(bo)叉等是(shi)否(fou)松(song)動(dong)。
3、檢查導(dao)管(guan)是(shi)否(fou)彎(wan)曲(qu)變(bian)形。
4、清(qing)除(chu)導(dao)管(guan)上(shang)積累的灰塵(chen),清掃(sao)時(shi)不(bu)可(ke)用力過(guo)大(da),以(yi)防(fang)損壞塑料(liao)導(dao)管(guan)。
5、導(dao)電器中(zhong)電刷磨(mo)情(qing)況(kuang),當電刷磨(mo)損到距(ju)離(li)其(qi)極限(xian)伸出位(wei)置小於(yu)2mm時(shi)應(ying)立即(ji)更(geng)換新(xin)的電刷。
6、檢查滾輪(lun)磨(mo)損狀況,滾輪(lun)能(neng)確保電刷在(zai)導(dao)管(guan)上(shang)下(xia)左(zuo)右的正確位置(zhi),滾輪(lun)磨(mo)損過度,亦會(hui)造成電刷磨(mo)損或繼續失(shi)電現象發生(sheng)。
(二)故(gu)障(zhang)處理
| 故(gu)障(zhang)現象 | 故(gu)障(zhang)原(yuan)因 | 處理方法(fa) |
| 斷電現象 | 1、電刷在(zai)導(dao)管(guan)中(zhong)爬坡 2、電刷磨(mo)損已超(chao)過有效(xiao)長度 3、導(dao)管(guan)接(jie)頭(tou)高低不(bu)平(ping) 4、單導(dao)電器 5、導(dao)軌(gui)連(lian)接不(bu)好(hao)(松(song)動(dong)) | 1、輕輕搖動(dong)導(dao)電器或導(dao)管(guan)、檢查導(dao)電器滾輪(lun)磨(mo)損情況,更換滾輪(lun)或導(dao)電器 |
| 導(dao)管(guan)明(ming)顯(xian)變(bian)形造(zao)成導(dao)電器無(wu)法(fa)移動(dong) | 1、環境(jing)局(ju)部溫(wen)度(du)過(guo)高 2、定形夾(jia)間(jian)距(ju)過大(da)或松(song)脫 3、浮動(dong)懸吊夾(jia)卡(ka)死導(dao)管(guan)熱(re)膨(peng)脹(zhang)無(wu)法(fa)延(yan)伸 4、缺少熱(re)膨(peng)脹(zhang)補(bu)償節(jie) | 1、采(cai)用(yong)隔(ge)熱(re)板(ban),室(shi)外應(ying)裝(zhuang)遮(zhe)陽(yang)板 2、增(zeng)加定形(xing)夾(jia),並(bing)進(jin)行(xing)校正(zheng) 3、調節(jie)浮(fu)動(dong)懸吊夾(jia),使導(dao)管(guan)能(neng)自由(you)延(yan)伸 4、增(zeng)加熱(re)膨(peng)脹(zhang)補(bu)償段(duan)(點(dian)) |
| 工(gong)作時(shi)導(dao)管(guan)晃(huang)動(dong)太大(da) | 1、撥(bo)叉未(wei)吸收傳(chuan)動(dong)誤(wu)差(cha) 2、安裝(zhuang)導(dao)管(guan)直(zhi)線度不(bu)好(hao) 3、定形夾(jia)松(song)動(dong) | 1、修正(zheng)撥(bo)叉,增(zeng)加各自由(you)度(du),吸收誤(wu)差(cha)環節(jie) 2、校正(zheng)導(dao)管(guan)的直線度 3、擰緊定(ding)形(xing)夾(jia)螺(luo)栓(shuan) |
| 電刷磨(mo)損太快(kuai) | 1、接(jie)頭不(bu)平(ping)整 2、載(zai)流量過(guo)大(da),電弧灼(zhuo)傷 3、彈(dan)簧(huang)壓(ya)力太(tai)大(da) | 1、按要(yao)求(qiu)重新(xin)連(lian)接導(dao)軌(gui) 2、增(zeng)加導(dao)電器在(zai)數量(liang) 3、減(jian)少彈(dan)簧(huang)壓(ya)力 |
| 電刷側(ce)面擦傷和(he)表面有粒(li)凹(ao)坑 | 1、導(dao)電器在(zai)導(dao)管(guan)內(nei)定(ding)位(wei)不(bu)好(hao),滾輪(lun)磨(mo)損,撥(bo)叉傳(chuan)遞側(ce)向(xiang)力大(da) 2、電刷與導(dao)管(guan)接(jie)觸不(bu)良產(chan)生(sheng)火花(hua)灼(zhuo)傷 3、電流過大(da) | 1、更(geng)換液(ye)輪(lun)或導(dao)電器更(geng)換撥(bo)叉 2、檢查導(dao)軌(gui)接頭(tou),使平(ping)整光(guang)滑,使電刷與導(dao)軌(gui)接觸面積60-90%,增(zeng)加導(dao)電器數(shu)量(liang) |
| 導(dao)電器滑(hua)行(xing)有較(jiao)大(da)聲(sheng)音 | 1、接頭(tou)不(bu)平(ping)整 | 1、按接頭(tou)工(gong)藝要(yao)求(qiu),重新(xin)處理 |
| 導(dao)電器外(wai)殼(ke)有擦(ca)痕 | 1、導(dao)管(guan)變(bian)形 2、導(dao)電器在(zai)定位(wei)不(bu)好(hao) | 1、導(dao)管(guan)開(kai)口尺(chi)寸(cun),狹(xia)窄(zhai),應(ying)撬大(da)槽口或增(zeng)加定形(xing)夾(jia) 2、更換導(dao)電器滾輪(lun) |
電話(hua)
微信掃(sao)壹(yi)掃(sao)